Problem |
 |
Possible Cause |
 |
Possible Solution |
 |
Motor overload of vacuum pump |
 |
Too much water is being supplied to the pump |
 |
Adjust water supply untill maximum vacuum is achieved with minimum water supply |
 |
|
 |
Current draw exceeds power of motor |
 |
Check the motor data tag |
 |
|
 |
Too less water is being supplied to the pump |
 |
Adjust water supply untill maximum vacuum is achieved with minimum water supply |
 |
|
 |
The exhaust line has a restriction or is not connected to a vent open to the atmosphere |
 |
Unclog the line / connect it to an open vent |
 |
Vacuum too low |
 |
Water too warm |
 |
Adjust water temperature (cold water produces more vacuum) |
 |
Barrel Heat Zone will not reach the set point |
 |
Heater band burned out |
 |
Replace heater band |
 |
|
 |
Pyrometer is not energized when the temperature drops below the set point |
 |
Replace the pyrometer |
 |
|
 |
Mercury contactor in control cabinet not energized or faulty |
 |
Replace mercury contactor |
 |
|
 |
Overload protection circuit breaker for the individual heater zone is not energized |
 |
Energize circuit breaker for appropriate zone |
 |
|
 |
Thermocouple is not seated in the thermocouple well |
 |
Seat the thermocouple well again |
 |
|
 |
Thermocouple or heater bands reversed at their zones (Example: Zone 2 thermocouple sensing a low temperature in Zone 2 and adding heat to Zone 1 |
 |
Switch thermocouple or heater band to the proper zone |
 |
|
 |
Cooling control solenoid stuck in the open position |
 |
Replace control solenoid |
 |
Heat zone overriding the set point |
 |
Pyrometer does not de-energize when the temperature exceeds the set point |
 |
Replace the pyrometer |
 |
|
 |
Pressure relief valve stuck in the open position |
 |
Replace the relief valve |
 |
|
 |
Thermocouple or heater bands reversed at their zones (Example: Zone 2 thermocouple sensing a low temperature in Zone 2 and adding heat to Zone 1 |
 |
Switch thermocouple or heater band to the proper zone |
 |
|
 |
Insufficient water flow through the heat exchanger. Heat exchanger is clogged or the globe valve is closed |
 |
Check hoses, unclog heat exchanger or open globe valve. Replace heat exchanger |
 |
|
 |
Solenoid for zone’s fluidcontrol not opening |
 |
Replace defective solenoid |
 |
|
 |
Defective pump, motor, thermal overload or coupling |
 |
Replace defective pump, motor or coupling |
 |
|
 |
Oil system plugged or clogged |
 |
Change oil filter. Clean and flush oil systems |
 |
Screw temperature will not reach the set point |
 |
Heater band is burned out |
 |
Replace the heater band |
 |
|
 |
Thermocouple is defective |
 |
Replace the thermocouple |
 |
|
 |
Pyrometer : Not energizing the mercury contactor |
 |
Replace the pyrometer |
 |
|
 |
Cooling solenoid continuously energized |
 |
Replace the solenoid |
 |
|
 |
Mercury contactor is defective |
 |
Replace the mercury contactor |
 |
|
 |
Cooling fluid solenoid valve is stuck open |
 |
Replace the solenoid valve |
 |
|
 |
Insufficient fluid flow: clogged filter |
 |
Change the filter |
 |
|
 |
Faulty pump, motor or coupling |
 |
Replace |
 |
|
 |
Oil system plugged or clogged |
 |
Change oil filter. Clean and flush oil system |
 |
Screw temperature overriding the set point |
 |
Pyrometer does not deenergize when the temperature exceeds the set point |
 |
Replace the pyrometer |
 |
|
 |
Thermocouple near the flow meter outlet is defective |
 |
Replace the thermocouple |
 |
|
 |
Insufficient water flow through the heat exchanger |
 |
Unclog or replace heat exchanger |
 |
|
 |
Water solenoid supply not energized or stuck in the close position |
 |
Replace the solenoid |
 |
|
 |
Cooling fluid solenoid valve stuck closed |
 |
Replace solenoid valve |
 |
|
 |
Pressure relief valve stuck open |
 |
Replace relief valve |
 |
|
 |
Filter clogged |
 |
Change filter |
 |
|
 |
Faulty pump, motor, thermal, overload or coupling |
 |
Replace |
 |
|
 |
Oil system plugged or clogged |
 |
Change oil filter. Clean and flush oil system |
 |
Insufficient vacuum for venting |
 |
Insufficient water flow |
 |
Check hose |
 |
|
 |
|
 |
Check hose clamps and manifold bolts for tightness |
 |
|
 |
|
 |
Check O-rings in sight glass |
 |
|
 |
|
 |
Clean out gate valve |
 |
|
 |
|
 |
Change the filter |
 |
|
 |
|
 |
Check solenoid valve |
 |
|
 |
|
 |
Check pump, motor and coupling |
 |
Excessive vibration |
 |
Poor coupling alignment at motor |
 |
Realign coupling |
 |
|
 |
Defective bearing in the reduction gearbox |
 |
Replace the bearing |
 |
|
 |
Defective bearing in the motor |
 |
Replace the bearing |
 |
Thumping noise in the rear of the machine |
 |
Defective bearing in the distributor gearbox |
 |
Replace defective bearing |
 |
|
 |
Rough spot on gear inside distributor gearbox |
 |
Remove rough spot on gear |
 |
|
 |
Poor coupling alignment between the reduction and distributor gearboxes |
 |
Realign coupling |
 |
Erratic drive RPM |
 |
Faulty speed board in DC drive |
 |
Replace speed board |
 |
|
 |
Faulty current board in DC drive |
 |
Replace current board |
 |
|
 |
Faulty input voltage to DC drive |
 |
Correct the voltage supply |
 |
|
 |
Excessive current being drawn from the drive |
 |
Check / Replace DC drive motor |
 |
Starve feeder auger does not operate |
 |
The reference potentiometer is set to zero |
 |
Reset or replace the potentiometer |
 |
|
 |
The control is not receiving the start input due to debris in the start button |
 |
Clean out control buttons |
 |
|
 |
The starting coil has not received an output from the control or is faulty |
 |
Check the connection and/or replace the starting coil |
 |
|
 |
The drive fuses have blown |
 |
Replace the fuses |
 |
|
 |
The feeder drive is faulty |
 |
Replace the motor |
 |
|
 |
The armature fuse has blown |
 |
Replace the fuse |
 |
|
 |
Optional signal conditioned card used for slaving the main extruder motor and the feed auger has failed |
 |
Replace the card |
 |
Starve feeder auger operates but will not achieve full speed |
 |
Main motor potentiometer is set low or to zero |
 |
Increase the setting of the main motor potentiometer |
 |
The entire extruder is overheating |
 |
The water saver solenoid has failed in the closed position or blown in related fuse |
 |
Check the solenoid valve and/or replace the fuse |
 |
|
 |
The cooling water supply to the extruder is dirty causing restricted flow or the supply pressure is insufficient |
 |
Change the filter or check the supply line for leaks |
 |