Screw (nitrided)

To be checked: Screw diameter (by measuring)
Extraordinary wear (by sight)
Maintenance Interval: Every 2500 operating hours
Lower Tolerance: -0,4 mm ( -> postnitriding)
-0,6 mm ( -> poss. second postnitriding)
Instruction: Measuring:
Check the external diameter at the above determined measuring points.
Register the progression of wear.
Register zones of extraordinary wear.
Note: Wear is superproportional when lower tolerance is surpassed.
To avoid superproportional wear replace screw and cylinder at the same time.
Measuring
Point
Length
in mm
Diameter after operating hours
2500 5000 7500 10000 12500
1
2
3
4
5
6