To be checked: |
Screw diameter (by measuring)
Extraordinary wear (by sight) |
 |
Maintenance Interval: |
Every 2500 operating hours |
 |
Lower Tolerance: |
-0,4 mm ( -> postnitriding)
-0,6 mm ( -> poss. second postnitriding) |
 |
Instruction: |
Measuring:
Check the external diameter at the above determined measuring points.
Register the progression of wear.
Register zones of extraordinary wear. |
 |
Note: |
Wear is superproportional when lower tolerance is surpassed.
To avoid superproportional wear replace screw and cylinder at the same time. |